SMART 전원 오류 설명

SMART 전원 오류 설명

나는 gsmartcontrol"오류"탭을 사용하는데 다음과 같이 말합니다.

Complete error log:

SMART Error Log Version: 1
ATA Error Count: 398 (device log contains only the most recent five errors)
    CR = Command Register [HEX]
    FR = Features Register [HEX]
    SC = Sector Count Register [HEX]
    SN = Sector Number Register [HEX]
    CL = Cylinder Low Register [HEX]
    CH = Cylinder High Register [HEX]
    DH = Device/Head Register [HEX]
    DC = Device Command Register [HEX]
    ER = Error register [HEX]
    ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 398 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 08 00 00  Error: ICRC, ABRT at LBA = 0x0000080f = 2063

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 08 00 40 00      00:09:15.084  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:09:15.006  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:09:14.990  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:09:14.974  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:09:14.959  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

Error 397 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 08 00 00  Error: ICRC, ABRT at LBA = 0x0000080f = 2063

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 08 00 40 00      00:09:14.756  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:09:14.678  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:09:14.662  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:09:14.646  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:09:14.631  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

Error 396 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 08 00 00  Error: ICRC, ABRT at LBA = 0x0000080f = 2063

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 08 00 40 00      00:09:14.508  READ FPDMA QUEUED
  60 01 00 02 00 00 40 00      00:09:14.506  READ FPDMA QUEUED
  60 04 00 07 00 00 40 00      00:09:14.506  READ FPDMA QUEUED
  60 01 00 00 00 00 40 00      00:09:14.506  READ FPDMA QUEUED
  60 01 00 00 00 00 40 00      00:09:14.506  READ FPDMA QUEUED

Error 395 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 88 b9 0a  Error: ICRC, ABRT at LBA = 0x0ab9880f = 179931151

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 88 b9 40 00      00:00:15.234  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:00:15.156  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:00:15.141  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:00:15.125  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:00:15.109  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

Error 394 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 57 d1 54 08  Error: ICRC, ABRT at LBA = 0x0854d157 = 139776343

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 00 50 d1 54 40 00      00:00:14.984  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:00:14.922  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:00:14.906  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:00:14.891  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:00:14.875  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

스마트 속성

무슨 뜻이에요? 이 오류를 방지하는 방법은 무엇입니까?

답변1

“ICRC의 실수”는 다음을 의미합니다.전송 중에 데이터가 손상되었습니다.;드라이브의 수명을 고려하면 가장 가능성이 높은 원인은 손상된 케이블입니다. 전체적으로 가능한 원인은 다음과 같습니다.

  • 케이블이 손상되었습니다. 문제가 해결되지 않으면 케이블을 다시 설치하고 교체해 보십시오.
  • 불량 칩셋(마더보드가 아주 오래되지 않은 경우 가능성은 낮음)
  • 운전을 잘하지 못합니다.

마지막 단계에 도달하면 다른 시스템에서 드라이브를 사용해 보고...드라이브라면 교체하는 데 문제가 없는지 확인하세요.

관련 정보