다음과 같은 오류가 발생합니다. 이는 무엇을 의미합니까?
Oct 19 01:02:25 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016841e00513,0 (sd6):
Oct 19 01:02:25 amra02 drive offline
Oct 19 01:02:25 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016841e00513,0 (sd6):
Oct 19 01:02:25 amra02 drive offline
Oct 19 01:02:25 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016841e00513,0 (sd6):
Oct 19 01:02:25 amra02 drive offline
Oct 19 01:03:07 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016041e00513,0 (sd5):
Oct 17 19:53:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 19:53:19 amra02 Command failed to complete...Device is gone
Oct 17 19:53:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 19:53:19 amra02 Command failed to complete...Device is gone
Oct 17 19:53:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 19:53:19 amra02 Command failed to complete...Device is gone
Oct 17 20:03:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 20:03:19 amra02 Command failed to complete...Device is gone
답변1
연결이 끊어졌습니다(예: 디스크에 대한 액세스).
5006016841e00513
id는 클라리온 컨트롤러이고,
6006016060702d0051a04cd7773de411
SAN의 LUN(또는 디스크)입니다.
- 공급업체Clariion
- 내선번호 060702d0051a04cd7773de411
- CI:LDEV (16) e4:11 (10) 228 - 17
하드웨어를 확인해야 하며, 하드웨어가 정상이면 SAN 스위치의 구역 구성을 확인해야 합니다.