RAID 구성 유틸리티에서 구성한 B120i
RAID 컨트롤러(FakeRAID)가 포함된 HP DL360e G8이 있습니다 . RAID 1
CentOS 7을 설치한 후 실행하면 fdisk -l
파티션 크기가 동일한 두 개의 별도 디스크가 표시됩니다.
단일 디스크(/dev/sda)가 표시되어야 합니다. 그렇죠?
Disk /dev/sda: 500.1 GB, 500107862016 bytes, 976773168 sectors
Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 4096 bytes
I/O size (minimum/optimal): 4096 bytes / 4096 bytes
Disk label type: dos
Disk identifier: 0x00020b93
Device Boot Start End Blocks Id System
/dev/sda1 * 2048 526335 262144 83 Linux
/dev/sda2 526336 8914943 4194304 82 Linux swap / Solaris
/dev/sda3 8914944 976707583 483896320 8e Linux LVM
Disk /dev/sdb: 500.1 GB, 500107862016 bytes, 976773168 sectors
Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 4096 bytes
I/O size (minimum/optimal): 4096 bytes / 4096 bytes
Disk label type: dos
Disk identifier: 0x00020b93
Device Boot Start End Blocks Id System
/dev/sdb1 * 2048 526335 262144 83 Linux
/dev/sdb2 526336 8914943 4194304 82 Linux swap / Solaris
/dev/sdb3 8914944 976707583 483896320 8e Linux LVM
답변1
단일 드라이브를 본다는 가정이 정확합니다.
즉, 나는 FakeRAID(BIOS 지원 RAID)에 대해 나쁜 경험을 했습니다.
대부분의 Linux 배포판에서는 제대로 작동하지 않습니다.
내 제안은 다음과 같습니다
BIOS에서 FakeRAID 비활성화
설치하다
mdadm
관리가 매우 쉽고 안정적인 소프트웨어 RAID 설정
안타깝게도 드라이브가 하나가 아닌 두 개로 표시되는 이유를 모르겠습니다.
성능 측면에서는 mdadm
CPU 작업 부하가 동일합니다. 전혀 차이가 없습니다. 보장됩니다.
부팅 가능한 RAID 사용에 대한 자세한 내용은 mdadm
다음을 참조하십시오.기사 중 하나를 참조하세요.귀하에게 가장 적합한 것은 무엇입니까?