# hddtemp
/dev/sda: DELL PERC H740P Adp: S.M.A.R.T. not available
/dev/sdb: DELL PERC H740P Adp: S.M.A.R.T. not available
# smartctl --scan
smartctl --scan
/dev/sda -d scsi # /dev/sda, SCSI device
/dev/sdb -d scsi # /dev/sdb, SCSI device
/dev/bus/0 -d megaraid,0 # /dev/bus/0 [megaraid_disk_00], SCSI device
/dev/bus/0 -d megaraid,1 # /dev/bus/0 [megaraid_disk_01], SCSI device
/dev/bus/0 -d megaraid,2 # /dev/bus/0 [megaraid_disk_02], SCSI device
/dev/bus/0 -d megaraid,3 # /dev/bus/0 [megaraid_disk_03], SCSI device
/dev/bus/0 -d megaraid,4 # /dev/bus/0 [megaraid_disk_04], SCSI device
/dev/bus/0 -d megaraid,5 # /dev/bus/0 [megaraid_disk_05], SCSI device
/dev/bus/0 -d megaraid,6 # /dev/bus/0 [megaraid_disk_06], SCSI device
/dev/bus/0 -d megaraid,7 # /dev/bus/0 [megaraid_disk_07], SCSI device
hddtemp
모든 디스크가 RAID 컨트롤러인 경우 Linux에서 이를 어떻게 사용합니까?
어떤 디스크의 온도는 중요하지 않습니다.
답변1
이것이 어떻게 이루어지는가지능형 제어hddtemp
...나는 이것이 배후에서 사용된다고 믿습니다 .
# using the results of smartctl --scan
smartctl --all -d megaraid,2 /dev/sda | grep Temp
Temperature Warning: Disabled or Not Supported
Current Drive Temperature: 27 C
Drive Trip Temperature: 70 C
거기에서 사용할 수 있는 현재 드라이브 온도 값을 얻을 수 있습니다. -